Über 30.000 Artikel am Lager
schneller Versand
30 Tage Geld-Zurück-Garantie
Bequemer Kauf auf Rechnung
Hotline 05223 - 79 44 8 - 0

Erler-zimmer Tetralogy of Fallot

335,87 € *

% 342,72 €* (2% gespart)

Versandkostenfrei

im Zulauf - versandfertig in 5 Tagen, Lieferzeit 2-8 Wochen

Menge
Stückpreis
Bis 2 Stk

335,87 €*

Bis 5 Stk

329,15 €*

-2 %
Bis 9 Stk

325,79 €*

-3 %
Ab 10 Stk

322,44 €*

-4 %
Stk
Produktnummer: EZMP2037
Hersteller: Erler-Zimmer
Sie erhalten 101 Bonus Punkte für diese Bestellung
Produktinformationen "Erler-zimmer Tetralogy of Fallot"

Produktinformationen "Tetralogy of Fallot"Clinical HistoryA 21-month old boy was admitted with a history of exhaustion and exertional dyspnoea for the previous 2 to 3 months. During this time there had been several attacks of acute dyspnoea each lasting up to two minutes. Examination revealed central cyanosis, mild finger clubbing, and a harsh systolic bruit maximal at the left sternal edge. Cardiac catheterisation led to a diagnosis of Fallots tetralogy and severe pulmonary oedema. A surgical correction was performed (Willis-Potts anastomosis between the aorta and the origin of the left pulmonary artery). The child developed acute dyspnoea and left lobar consolidation 12 hours post-operatively and died despite treatment.PathologyThe childs heart is viewed from the anterior aspect. The anterior wall of the right ventricle has been excised to reveal prominent right ventricular hypertrophy and a narrowed pulmonary outflow tract. The pulmonary valve ring is also small, with a bicuspid stenosed valve. There is a patch of endocardial fibrosis in the outflow tract below the pulmonary valve. The origin of the aorta overlies a high ventricular septal defect. A probe could be passes into the aorta from the hypertrophied right ventricle. The further probe was able to be passed from the narrowed pulmonary trunk into a dilated, thin-walled left pulmonary artery and through the surgical anastomosis into the descending aorta. Examination of the posterior aspect of the specimen reveals an opened right atrium and left ventricle. When viewed from the right side of the heart, there is a large atrial septal defect (ASD), 8 mm in diameter at the site of the foramen ovale (large arrow). Another tiny ASD (small arrow) 3 mm in diameter is present posterior to the upper border of the large ASD. Note that the wall of the left ventricle is slightly thinner than the wall of the right ventricle.Further Information The four features of tetralogy of Fallot are: 1. Ventricular septal defect (VSD) 2. An aorta that straddles the VSD with the latter communicating with both ventricles (over-riding aorta) instead of just the left ventricle 3. Pulmonary stenosis or obstruction of the right ventricular overflow tract 4. Right ventricular hypertrophy. This condition usually causes cyanosis early in life. Its severity depends on the degree of pulmonary outflow obstruction, which determines whether there is a left-to-right, or right-to-left shunt. In some patients, pulmonary blood flow is increased due to the presence of a patent ductus arteriosus. Patients with this condition may survive untreated into adult life, and a few may reach middle age. However, surgical correction is now possible and is desirable, as the disorder is ultimately fatal. Sometimes additional cardiac abnormalities may be present. (e.g. atrial septal defect, as was found in this case).In most cases of tetralogy of Fallot, the cause is not known although in some patients, genetic factors play a role. For example, the condition is more common in patients with Down syndrome (Trisomy 21 in association with AV canal defects) or DiGeorge syndrome (22q11 deletion).Weiterführende Links zu "Tetralogy of Fallot" Fragen zum Artikel? Weitere Artikel von Nicht angegeben

Eigenschaften "Erler-zimmer Tetralogy of Fallot"
Tierfuttertyp: Ergänzungsfuttermittel

Vorteile
  • Individuelle Beratung von Produktexperten
  • Kostenloser Versand ab € 200,- innerhalb Deutschland
  • Inklusive 5 Jahre Garantie
  • Versand innerhalb von 24h*
  • Weltweiter Versand

Unsere Vision ist unsere Passion. 

Als 4. Generation sehen wir uns verpflichtet alte Werte mit frischem Wind zu ergänzen. Aufgewachsen im Unternehmen lernten wir sehr früh dass Qualität und Kundenorientierung nicht nur Worte sind. Bei uns sind das gelebte Ziele und Werte. Gemeinsam mit Ihnen möchten wir die medizinische Aus- und Weiterbildung verbessern. Wir und das ganze Erler-Zimmer Team freuen uns auf eine lebendige Zusammenarbeit. Auf unserer Webseite möchten wir Sie mit auf die Reise durch eines der umfangreichsten Produktsortimente der Welt nehmen. 
Patrick Probst & Mathias Probst

Erstklassige Qualität in allen Produkten & Prozessen 

Alle Geschäftsprozesse sind so optimiert, dass Fehler so gut wie ausgeschlossen werden können. Grundsätzlich steht aber die Kundenzufriedenheit im Vordergrund. Dies bedeutet, dass Prozesse auch auf Grund von Kundenwünschen modifiziert werden können, das macht uns flexibel und sorgt für ein Höchstmaß an Kundenorientierung. In der Herstellung der Produkte verfügt jeder Produktionsschritt über eine Qualitätsprüfung. Fehlerhafte Teile werden erst gar nicht zum fertigen Produkt. 

Neueste Technologie – am Puls der Zeit

Modernes Produktdesign mit neuesten CAD – Technologien. Verschiedene Prototyping – Verfahren, darunter modernster Vollfarbe – 3D Druck. Professionelle Kunststofffertigung aller gängigen Materialien. Passende Maschinengrößen für die wirtschaftliche Fertigung unterschiedlichster Projekte. Optimierte Abläufe in Verwaltung und Produktion unter Verwendung von SAP sorgen für schnelle und kundenorientierte Bearbeitung aller Projekte. Ein papierloses Büro verkürzt Bearbeitungszeiten und schont dabei auch noch die Umwelt.

0 von 0 Bewertungen

Geben Sie eine Bewertung ab!

Teilen Sie Ihre Erfahrungen mit dem Produkt mit anderen Kunden.