Über 30.000 Artikel am Lager
schneller Versand
30 Tage Geld-Zurück-Garantie
Bequemer Kauf auf Rechnung
Hotline 05223 - 79 44 8 - 0

Erler-zimmer Atrial septal defect

1.071,74 € *

% 1.093,61 €* (2% gespart)

Versandkostenfrei

im Zulauf - versandfertig in 5 Tagen, Lieferzeit 2-8 Wochen

Menge
Stückpreis
Bis 2 Stk

1.071,74 €*

Bis 5 Stk

1.050,31 €*

-2 %
Bis 9 Stk

1.039,59 €*

-3 %
Ab 10 Stk

1.028,87 €*

-4 %
Stk
Produktnummer: EZMP2032
Hersteller: Erler-Zimmer
Sie erhalten 322 Bonus Punkte für diese Bestellung
Produktinformationen "Erler-zimmer Atrial septal defect"

Produktinformationen "Atrial septal defect"Clinical HistoryA 10-year-old girl with a known congenital heart was admitted for surgical repair because of the recent onset of cyanosis and cardiac failure. On examination, she was breathless with a blood pressure of 105/60mm/Hg and a pulse rate of 140/min. There was a loud heart murmur in the fourth left intercostal space adjacent to the sternum. The jugular venous pressure was elevated, and there were bilateral pulmonary basal crepitations but no peripheral oedema. At operation, the defect was repaired however, death followed a sudden post-operative deterioration of unknown cause.Pathology The heart is viewed from the left side. The left atrium has been opened to display a large ovoid defect 3.5 cm in greatest diameter in the inter-atrial septum. Only a small postero-inferior crescentic rim of septum remains. The left ventricle is small, and the right ventricle is hypertrophied (see posterior aspect of specimen where part of the right postero-lateral wall of the right ventricle has been cut away to demonstrate the thickened wall). The pulmonary artery, seen to the left of the atrial cavities, is greatly enlarged. The smaller vessel seen lying above the cut end of the pulmonary artery is the aortic arch. The cut edge of a lumen 8 mm in diameter immediately below the cut end of the pulmonary artery is the left auricular appendage.Further InformationAtrial septal defect is usually asymptomatic early in life, even when large. Symptoms may not develop until adult life. The onset of symptoms is due to reversal of the initial left-to-right shunt as a result of increasing right ventricular hypertrophy and pulmonary hypertension. The ensuing right-to-left shunt is associated with cyanosis and dyspnoea, and ultimately leads to congestive cardiac failure.There are several types of atrial septal defects, including:Secundum - This is the most common type of ASD and occurs in the middle of the wall between the atria (atrial septum). Primum - This defect occurs in the lower part of the atrial septum and might occur with other congenital heart problems.Sinus venosus - This rare defect usually occurs in the upper part of the atrial septum and is often associated with other congenital heart problems.Coronary sinus - In this rare defect, part of the wall between the coronary sinus which is part of the vein system of the heart and the left atrium is missing.It is not known why all atrial septal defects occur, but some congenital heart defects appear to be familial and sometimes occur with other genetic problems, such as Trisomy 21 (Down’s syndrome). Some conditions during pregnancy can increase the risk of having a baby with a heart defect, including acute infections such as Rubella infection drug, tobacco or alcohol use, or exposure to certain substances (such as cocaine) during the first trimester of pregnancy and underlying systemic conditions, such as diabetes or systemic lupus erythematosus.Weiterführende Links zu "Atrial septal defect" Fragen zum Artikel? Weitere Artikel von Nicht angegeben

Eigenschaften "Erler-zimmer Atrial septal defect"
Tierfuttertyp: Ergänzungsfuttermittel

Vorteile
  • Individuelle Beratung von Produktexperten
  • Kostenloser Versand ab € 200,- innerhalb Deutschland
  • Inklusive 5 Jahre Garantie
  • Versand innerhalb von 24h*
  • Weltweiter Versand

Unsere Vision ist unsere Passion. 

Als 4. Generation sehen wir uns verpflichtet alte Werte mit frischem Wind zu ergänzen. Aufgewachsen im Unternehmen lernten wir sehr früh dass Qualität und Kundenorientierung nicht nur Worte sind. Bei uns sind das gelebte Ziele und Werte. Gemeinsam mit Ihnen möchten wir die medizinische Aus- und Weiterbildung verbessern. Wir und das ganze Erler-Zimmer Team freuen uns auf eine lebendige Zusammenarbeit. Auf unserer Webseite möchten wir Sie mit auf die Reise durch eines der umfangreichsten Produktsortimente der Welt nehmen. 
Patrick Probst & Mathias Probst

Erstklassige Qualität in allen Produkten & Prozessen 

Alle Geschäftsprozesse sind so optimiert, dass Fehler so gut wie ausgeschlossen werden können. Grundsätzlich steht aber die Kundenzufriedenheit im Vordergrund. Dies bedeutet, dass Prozesse auch auf Grund von Kundenwünschen modifiziert werden können, das macht uns flexibel und sorgt für ein Höchstmaß an Kundenorientierung. In der Herstellung der Produkte verfügt jeder Produktionsschritt über eine Qualitätsprüfung. Fehlerhafte Teile werden erst gar nicht zum fertigen Produkt. 

Neueste Technologie – am Puls der Zeit

Modernes Produktdesign mit neuesten CAD – Technologien. Verschiedene Prototyping – Verfahren, darunter modernster Vollfarbe – 3D Druck. Professionelle Kunststofffertigung aller gängigen Materialien. Passende Maschinengrößen für die wirtschaftliche Fertigung unterschiedlichster Projekte. Optimierte Abläufe in Verwaltung und Produktion unter Verwendung von SAP sorgen für schnelle und kundenorientierte Bearbeitung aller Projekte. Ein papierloses Büro verkürzt Bearbeitungszeiten und schont dabei auch noch die Umwelt.

0 von 0 Bewertungen

Geben Sie eine Bewertung ab!

Teilen Sie Ihre Erfahrungen mit dem Produkt mit anderen Kunden.